本文已被:浏览 12次 下载 0次
投稿时间:2024-02-27 修订日期:2024-04-10
投稿时间:2024-02-27 修订日期:2024-04-10
中文摘要: 为了解决大规模风能以及光伏并网波动对电网安全稳定运行的影响。通过分析风力发电、光伏发电、水利发电和抽水蓄能的互补特性,将风力发电、光伏发电、水利发电电和抽水蓄能作为一个完整的互补发电系统。考虑多种功率约束,提出了互补系统波动最小和火电机组等效负荷波动最小的两种最优调度模型。 然后使用改进的ADWOA算法对这两个模型仿真实验。仿真结果表明,两种最优调度模型都能很好地跟踪优化目标,减小风力发电和光伏并网的影响。
Abstract:In order to solve the impact of large-scale wind energy and photovoltaic grid-connected fluctuations on the safe and stable operation of the power grid. By analyzing the complementary characteristics of wind power generation, photovoltaic power generation, hydro power generation and pumped storage, wind power generation, photovoltaic power generation, hydro power generation and pumped storage power generation are regarded as a complete complementary power generation system. Considering various power constraints, two optimal scheduling models with minimum fluctuation of complementary system and minimum fluctuation of equivalent load of thermal power unit are proposed. Then the improved ADWOA algorithm is used to simulate the two models. The simulation results show that the two optimal scheduling models can track the optimization target well and reduce the influence of wind power generation and photovoltaic grid connection.
keywords: Power grid security Complementary system ADWOA
文章编号:20240227001 中图分类号: 文献标志码:
基金项目:
作者 | 单位 | 邮编 |
李庆豪* | 广东电网有限责任公司惠州供电局 | 516300 |
李晓莉 | 广东电网有限责任公司惠州供电局 | |
郭志达 | 广东电网有限责任公司惠州供电局 | |
陈远欣 | 广东电网有限责任公司惠州供电局 | |
姚远湘 | 广东电网有限责任公司惠州供电局 | |
赵岭 | 广东电网有限责任公司惠州供电局 | |
萧名谦 | 广东电网有限责任公司惠州供电局 |
引用文本: